Coating material:RuO₂, IrO₂, Ta₂O₅, or Mixed Metal Oxide (MMO)
Coating thickness:5–10 μm
Operating voltage:1.5 – 12 V
Current density:100 – 5000 A/m²
Working temperature:Up to 80°C
Service life:5 – 10 years (depending on electrolyte composition)
Titanium Anodes for Water Treatment - Premium DSA Technology
Baoji City ShenAo Metal Materials Co., Ltd. brings you professional titanium anodes for water treatment backed by 17 years of manufacturing excellence. Our Dimensionally Stable Anodes (DSA) feature high-purity Grade 1/2 titanium substrates coated with advanced Mixed Metal Oxide (MMO) layers of RuO₂, IrO₂, or Ta₂O₅. With coating thickness precision of 5–10 μm, these anodes deliver exceptional performance at current densities from 100 to 5000 A/m². Operating reliably at temperatures up to 80°C, our products ensure 5–10 years of continuous service life. Manufactured in China's Titanium Valley using mature bimetallar explosive welding technology, we guarantee timely delivery and strict quality standards for your industrial applications.
What Makes Our Titanium Anodes Different?
Your water treatment challenges request solid arrangements. The item from ShenAo combine cutting-edge materials science with demonstrated electrochemical performance.
Our anodes illuminate issues that conventional cathodes essentially cannot handle. You get dimensional steadiness that keeps up reliable inter-electrode dispersing all through the benefit life. This implies steady cell voltage and unsurprising working costs.
The titanium substrate gives unmatched chemical resistance. Whether you're working with acidic situations or high-chloride arrangements, these anodes perform consistently.
Superior Electrocatalytic Performance
We optimize coating definitions to diminish overpotential essentially. This interprets straightforwardly to lower vitality utilization for your facility.
The progressed MMO coating catalyzes particular responses effectively. You accomplish way better treatment comes about whereas lessening operational costs.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Technical Specifications
|
Parameter
|
Specification
|
|
Base Material
|
Grade 1 / Grade 2 Titanium (ASTM B265)
|
|
Coating Type
|
RuO₂, IrO₂, Ta₂O₅, MMO
|
|
Coating Thickness
|
5–10 μm
|
|
Operating Voltage
|
1.5–12 V
|
|
Current Density
|
100–5000 A/m²
|
|
Working Temperature
|
Up to 80°C
|
|
Service Life
|
5–10 years
|
|
pH Range
|
0–14
|
Where Your Industries Benefit Most?
Industrial Wastewater Electrochemical Oxidation
Pharmaceutical and textile facilities face tough challenges with refractory organic compounds. Your biological systems cannot handle these toxic substances effectively.
Our anodes break down high-concentration COD and BOD through advanced electro-oxidation. You achieve compliance with environmental discharge limits without expensive chemical additives.
Landfill leachate contains complex matrices with high ammonia nitrogen. Traditional methods fail here. These titanium anodes for water treatment excel at degrading these persistent contaminants.
Maritime Ballast Water Management
Shipboard systems require reliability in harsh conditions. Our anodes perform in-situ electro-chlorination in high-salinity, high-pressure seawater environments.
You eliminate invasive aquatic species while meeting international maritime compliance standards. The dimensional stability ensures consistent performance throughout long voyages.
Electrochemical Scale Prevention
Industrial cooling towers and desalination systems suffer from heat exchanger fouling. You traditionally relied on anti-scalant chemicals.
Our anodes precipitate hardness ions like Ca²⁺ and Mg²⁺ onto the cathode electrochemically. This prevents scaling even under high-temperature and high-alkalinity conditions.
You reduce chemical costs and maintenance downtime simultaneously.
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Product production process
|
|
|
|
|
|
|
|
|
|
|
|
Why Choose ShenAo Metal Materials?
17 Years of Manufacturing Excellence
We've built our notoriety on reliable quality and solid conveyance. Our generation office in Baoji High-tech Mechanical Advancement Zone utilizes progressed forms idealized over about two decades.
Hundreds of non-ferrous metal gear producers believe us as their long-term provider. Your ventures advantage from this demonstrated track record.
Customization for Your Correct Requirements
Every application has interesting requests. We give custom-made arrangements coordinating your particular electrolyte composition, current thickness needs, and dimensional requirements.
Whether you require little bunch testing or large-scale generation, we convey on time with ensured quality.
Complete Quality Assurance
Our strict prepare innovation guarantees each anode meets thorough measures. We test coating judgment and substrate virtue completely some time recently shipment.
You get items that perform as indicated from day one.
|
|
|
|
|
|
|
|
|
Application Industries
|
|
|
|
|
|
|
|
Our Factory
Our Patents and Honors
Our Packaging
|
|
|
|
|
|
|
|
|
|
|
|
Frequently Asked Questions
Q: How long will these anodes last in my application?
A: Depending on your current density and electrolyte composition, expect 5-10 years of service life. We conduct Accelerated Life Testing to verify performance under your specific conditions.
Q: Can I reuse the titanium substrate after coating depletion?
A: Absolutely. Once the coating is exhausted, we can chemically strip and recoat the substrate. This significantly reduces your long-term capital expenses.
Q: What causes premature anode failure?
A: High fluoride concentrations above 50ppm, reverse polarity incidents, and mechanical coating abrasion are the primary causes. Proper installation and operation prevent these issues.
Q: How do I select the right coating for my process?
A: Ruthenium-Iridium coatings optimize chlorine evolution for brine electrolysis applications. Iridium-Tantalum coatings excel at oxygen evolution in acidic electroplating environments. Contact us to discuss your specific wastewater characteristics.
Q: How do you verify coating thickness?
A: We use non-destructive X-ray thickness gauges and precise weight-gain methods. This ensures compliance with specified noble metal loading requirements.
Q: What current density should I operate at?
A: This depends on your treatment objectives and electrolyte. We typically recommend 500-2000 A/m² for most industrial wastewater applications. Our technical team will help optimize parameters for your system.
Get Your Custom Solution Today
Ready to improve your Titanium anodes for water treatment efficiency? Contact our team at zh@baojiti.com.cn to discuss your specific requirements and receive expert technical guidance.